Hiện chưa có sản phẩm nào trong giỏ hàng của bạn
Chống sét van 48kV 10kA Class1 + Phụ kiện - Protektel/ Ba Lan (Poland)
- 10%

Chống sét van 48kV 10kA Class1 + Phụ kiện - Protektel/ Ba Lan (Poland)


Tình trạng:
8.840.000 đ
7.956.000 đ
  • - Mã sản phẩm:
  • CSV48-Protektel
  • - Đơn vị tính:
  • Cái

Chống sét van 48kV 10kA Class1 + Phụ kiện Ur=48kV, Uc(MOC)=38.4kV PROXAR-IN 48 AC - Protektel/ Ba Lan (Poland)

Usakan - 09.11.2023

  • Tứ Hiệp Plaza, Tứ Hiệp, Thanh Trì, Hà Nội,
  • Còn 100 sản phẩm
  • Điện thoại: 0978617363
Số lượng
Thêm vào giỏ hàng

PROXAR-IN AC/KK/06/EN edition 04.2019 page.1
MEDIUM VOLTAGE
SURGE ARRESTER
TYPE PROXAR-
IN AC
IN SILICONE HOUSING
CATALOGUE CARD

APPLICATION
Surge arresters type PROXAR-IN AC in silicone housing are intended for protection AC power engineering networks
against multiple lightning and switching overvoltages in MV substations, cables and transformers. This surge arrester
is destined to all special technical requirements as well.

OPERATING CONDITIONS
Surge arresters adapted for outdoor and indoor installation, temperate and tropical climate up to 1000 m over the sea
level. The possibility for install in any working positions. Working temperature -45
C to +60 C.
ADVANTAGES
- Low residual voltage
- High energy input capacity
- Stable U-I characteristics even after multiple strokes
- Housing resistant to rough handling
- Explosion and shatter – resistant design
- Pollution resistant and UV
- Ability to install in any position (vertically or horizontally)
- Maintenance free
- Low weight, easy transportation and storage

ADDITIONAL EQUIPMENT
The surge arrester can be equipped with additional line and ground accessories. At the customer's request and after
agreeing with the manufacturer, any type of accessories can be supplied.

ELECTRICAL DATA

Arrester classification according to EN 60099-4: 2014
Line discharge class according to IEC 60099-4: 2009
System voltage (Um)
Rated voltage (Ur)
Nominal discharge current In 8/20
s
High current impulse Ihc 4/10
s
Rated repetitive charge transfer rating Qrs
Rated thermal Energy Qth
Long duration current impulse, 2000
s
Short circuit rating
Maximal level of partial discharges
DH(Distribution High)
1
3.6 – 36 kV
1.2 – 48 kV
10 kA
100 kA
0.4 C
1.1 C
325 A
31.5 kA/0.2s
≤5 pC

Service conditions:
- ambient temperature -45
C do +60 C*
- altitude up to 1000 m*

- frequency
Mechanical data:
48 – 62 Hz

- specified long-term load (SLL) 210 Nm
- specified short-term load (SSL) 336 Nm
- torsional strength 50 Nm

*) for higher parameters please contact with manufacturer
PROXAR-IN AC/KK/06/EN edition 04.2019 page.2

TYPE
PROXAR-
IN AC
Rated
voltage
Ur
Maximum
operating
voltage
Uc
Residual voltage in [kV] pk at a specified impulse current
Wave 1/…
µs
Wave 8/20 µs Wave 30/60 µs
10kA 2.5kA 5kA 10kA 20kA 125A 250A 500A
kV kV kV kV kV kV kV kV kV kV
1.2 1.2 1.0 3,55 2.8 2.9 3.2 3.5 2.3 2.3 2.4
2.2 2.2 1.8 6,49 5.0 5.4 5.9 6.5 4.2 4.3 4.5
2.5 2.5 2.0 7,38 5.7 6.1 6.8 7.4 4.7 4.9 5.1
3 3 2.4 8,85 6.9 7.4 8.1 8.8 5.7 5.9 6.1
4 4 3.2 11,68 9.2 9.8 10.8 11.8 7.6 7.8 8.2
5 5 4.0 14,60 11.5 12.3 13.5 14.7 9.5 9.8 10.2
6 6 4.8 17,52 13.8 14.7 16.2 17.7 11.4 11.7 12.2
7 7 5.6 20,44 16.1 17.2 18.9 20.6 13.3 13.7 14.3
8 8 6.4 23,29 18.4 19.7 21.6 23.5 15.2 15.7 16.3
9 9 7.2 26,20 20.7 22.1 24.3 26.5 17.1 17.6 18.3
10 10 8.0 29,11 23.0 24.6 27.0 29.4 19.0 19.6 20.4
11 11 8.8 32,02 25.2 27.0 29.7 32.4 20.8 21.5 22.4
12 12 9.6 34,93 27.5 29.5 32.4 35.3 22.7 23.5 24.5
13 13 10.4 37,84 29.8 31.9 35.1 38.3 24.6 25.4 26.5
14 14 11.2 40,75 32.1 34.4 37.8 41.2 26.5 27.4 28.5
15 15 12.0 43,67 34.4 36.9 40.5 44.1 28.4 29.4 30.6
16 16 12.8 46,58 36.7 39.3 43.2 47.1 30.3 31.3 32.6
17 17 13.6 49,49 39.0 41.8 45.9 50.0 32.2 33.3 34.7
18 18 14.4 52,40 41.3 44.2 48.6 53.0 34.1 35.2 36.7
19 19 15.2 55,31 43.6 46.7 51.3 55.9 36.0 37.2 38.7
20 20 16.0 58,22 45.9 49.1 54.0 58.9 37.9 39.2 40.8
21 21 17.0 61,99 48.9 52.3 57.5 62.7 40.4 41.7 43.4
22 22 17.6 64,04 50.5 54.1 59.4 64.7 41.7 43.1 44.8
23 23 18.4 66,95 52.8 56.5 62.1 67.7 43.6 45.0 46.9
24 24 19.2 69,86 55.1 59.0 64.8 70.6 45.5 47.0 48.9
25 25 20.0 72,78 57.4 61.4 67.5 73.6 47.4 48.9 51.0
26 26 20.8 75,69 59.7 63.9 70.2 76.5 49.3 50.9 53.0
27 27 21.6 78,60 62.0 66.3 72.9 79.5 51.2 52.9 55.0
28 28 22.4 81,51 64.3 68.8 75.6 82.4 53.1 54.8 57.1
29 29 23.2 84,42 66.6 71.3 78.3 85.3 55.0 56.8 59.1
30 30 24.0 87,33 68.9 73.7 81.0 88.3 56.9 58.7 61.2
33 33 26.4 96,06 75.7 81.1 89.1 97.1 62.5 64.6 67.3
36 36 28.8 104,80 82.6 88.5 97.2 105.9 68.2 70.5 73.4
39 39 31.2 113,53 89.5 95.8 105.3 114.8 73.9 76.3 79.5
42 42 33.6 122,26 96.4 103.2 113.4 123.6 79.6 82.2 85.6
44 44 35.2 128,10 101.0 108,1 118.8 129.4 83.4 86.1 89.7
45 45 36.0 131,00 103.3 110.6 121.5 132.4 85.3 88.1 91.7
48 48 38.4 139,73 110.2 117.9 129.6 141.2 91.0 94.0 97.8

There is a possibility of manufacturing surge arresters for different voltages that are not listed in the table.
TOV CHARACTERISTIC
Power frequency voltage versus time
characteristic TOV without prior duty

UTOV for t=1 s
U
TOV for t=3 s
U
TOV for t=10 s
1.178 Ur = 1.473 Uc
1.150 Ur = 1.438 Uc
1.119 Ur = 1.399 Uc

Power frequency voltage versus time
characteristic TOV with prior energy
1.1 As.

UTOV for t=1 s
U
TOV for t=3 s
U
TOV for t=10 s
1.109 Ur = 1.386 Uc
1.078 Ur = 1.348 Uc
1.040 Ur = 1.300 Uc

TOV characteristic for PROXAR-IN AC
PROXAR-IN AC/KK/06/EN edition 04.2019 page.3
TECHNICAL DATA FOR HOUSING

Type
PROXAR-
IN AC
Insulation withstand
voltage of housing
Minimal distances Height
H
Crepage
distance
Flash-over
distance
Housing
number
Weight
50 Hz wet
(60s)
1.2/50 µs
dry
Distance
between
arresters „b”
Distance between
arrester and the
nearest grounded
structure „a”
kV kV mm mm mm mm mm No kg
1.2 10 21 105 58 80 127 100 01 0.27
2.2 105 58 0.29
2.5 105 58 0.30
3 105 58 0.31
4 17 35 105 58 96 143 113 02 0.47
5 105 59 0.48
6 105 68 0.49
7 26 54 105 77 118 242 137 03 0.62
8 105 85 0.63
9 110 94 0.64
10 34 70 119 103 137 338 157 04 0.72
11 127 111 0.73
12 136 120 0.74
13 42 88 145 129 158 436 181 05 0.92
14 153 137 0.93
15 162 146 0.94
16 60 125 171 155 198 555 217 06 1.19
17 179 163 1.20
18 188 172 1.21
19 197 181 1.22
20 205 189 1.23
21 214 198 1.24
22 223 207 1.25
23 84 174 231 215 257 767 277 07 1.61
24 240 224 1.62
25 249 233 1.63
26 257 241 1.64
27 266 250 1.65
28 275 259 1.66
29 283 267 1.67
30 292 276 1.68
33 105 218 318 302 308 972 331 08 2.00
36 344 328 2.04
39 130 270 370 354 368 1187 391 09 2.47
42 396 380 2.50
44 413 397 2.52
45 422 406 2.53
48 448 432 2.57

Note: It is possible to make a surge arrester in a different housing than the catalog version.
Fig. Surge arrester PROXAR-IN AC

The drawings above show the PROXAR-IN AC surge arrester. Surge arrester can work in a vertical position fig.1,
inverted position fig.2 and horizontal position fig.3.

Fig. 4. Minimal mounting distances
of surge arresters

PROXAR-IN AC/KK/06/EN edition 04.2019 page.4
Fig.5. Equipment for surge arrester type PROXAR-
IN AC
PROXAR-IN AC/KK/06/EN edition 04.2019 page.5
Order configurator**:

I II III IV V VI VII VIII
PROXAR-IN AC
VIII. Housing number
See table – TECHNICAL DATA FOR HOUSING Housing number

**) Empty fields to fill
II. Rated voltage Ur
See table – TECHNICAL DATA
Ur
III.
Voltage tyoe
Alternating voltage (48 – 62 Hz)
AC
IV.
Assembly (according Fig. 1; 2; 3)
– Vertical
1
– Reversed 2
– Horizontal 3
V.
Line accessories (according fig. 5)
– without line terminal
0
– line terminal 1 1
– line terminal 2 2
– line termianl 3 3
VI.
Earth accessories (according fig. 5)
– without earth terminal
0
– insulating bracket with disconnector 1 (Ur ≤ 30kV) 1
– earth terminal 2 2
– earth terminal 3 3
– vertical bracket 4 4
– horozontal bracket 5 5
– horizontal bracket 6 6
– bracket Z 7 7
- insulating bracket with disconnector 8 (Ur > 30kV) 8
- earth terminal 9 9
- insulating bracket A A
- insulating bracket B B
VII.
Accessories (according fig. 5)
– without anti-bird cap
0
– With anti-bird cap 1 1
Order example:

I II III IV V VI VII VIII
PROXAR-IN 22 AC 1 1 0 1 0 6

PROXAR-IN 22 AC 110106 – 3 pcs.
Description: Surge arrester type
PROXAR-IN of rated voltage Ur=22kV for AC system in vertical mounting version -1,
line terminal -
1, without earth terminal - 0, with bird cap 1, housing number – 06,
PROTEKTEL Sp. z o.o.
Piłsudskiego 92 str.;
PL 06-300 Przasnysz
Poland
Tel./Fax +48 029 7525784
E-mail:
protektel@protektel.pl
www.protektel.pl

ATTENTION
The manufacturer reserves the right to change technical data or designee without prior notice
.
PROXAR
® is a registered trademark newest family of surge arresters produced by Protektel
I. Type of product
PROXAR-IN

Vui lòng liên hệ : CÔNG TY CỔ PHẦN USAKAN VIỆT NAM
Hotline : 
0886687716
Điện thoại : 0978617363

Chống sét van 48kV 10kA Class1 + Phụ kiện Ur=48kV, Uc(MOC)=38.4kV PROXAR-IN 48 AC - Protektel/ Ba Lan (Poland)

Usakan - 09.11.2023